美文网首页
2021-08-06 配置监控邮件告警

2021-08-06 配置监控邮件告警

作者: 阿丧小威 | 来源:发表于2021-08-06 14:54 被阅读0次

1. 部署Alertmanager

安装包下载
地址1:https://prometheus.io/download/
地址2:https://github.com/prometheus/alertmanager/releases
下载部署Linux版Alertmanager

tar zxf alertmanager-0.22.2.linux-amd64.tar.gz
mv alertmanager-0.22.2 /usr/local/alertmanager
vi /usr/lib/systemd/system/alertmanager.service
[Unit]
Description=alertmanager
[Service]
ExecStart=/usr/local/alertmanager/alertmanager --config.file=/usr/local/alertmanager/alertmanager.yml
ExecReload=/bin/kill -HUP $MAINPID
KillMode=process
Restart=on-failure
[Install]
WantedBy=multi-user.target

指定告警规则文件路径

vi /usr/local/prometheus/prometheus.yml
rule_files:
   - "rules/*.yml"

配置告警规则

mkdir /usr/local/prometheus/rules
vi /usr/local/prometheus/rules/general.yml
groups:
- name: general #告警规则组名称
  rules:
  # 任何实例3分钟内无法访问发出告警
  - alert: 主机状态 # 告警规则名称
    expr: up == 0 # 基于PromQL的触发条件
    for: 3m # 等待评估时间
    labels: # 自定义标签
      severity: critical
    annotations: # 指定附加信息
      summary: "{{ $labels.instance }} 停止工作"
      description: "{{ $labels.instance }}:job {{ $labels.job }} 已经停止3分钟以上."

  - alert: CPU使用率
    expr: 100 - (avg(irate(node_cpu_seconds_total{mode="idle"}[5m])) by (instance) *100) > 80
    for: 5m
    labels:
      severity: warning
    annotations: 
      summary: "{{ $labels.instance }}CPU使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} CPU使用率大于80%,(当前值: {{ $value }})"
  - alert: CPU使用率
    expr: 100 - (avg(irate(node_cpu_seconds_total{mode="idle"}[5m])) by (instance) *100) > 90
    for: 5m
    labels:
      severity: critical
    annotations:
      summary: "{{ $labels.instance }}CPU使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} CPU使用率大于90%,(当前值: {{ $value }})"

  - alert: Memery使用率
    expr: (100 - (((node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes)/node_memory_MemTotal_bytes) * 100)) > 80
    for: 5m
    labels: 
      severity: warning
    annotations:
      summary: "{{ $labels.instance }}内存使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} 内存使用率大于80%,(当前值: {{ $value }})"
  - alert: Memery使用率
    expr: (100 - (((node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes)/node_memory_MemTotal_bytes) * 100)) > 90
    for: 5m
    labels:
      severity: critical
    annotations:
      summary: "{{ $labels.instance }}内存使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} 内存使用率大于90%,(当前值: {{ $value }})"

  - alert: Disk使用率
    expr: (1-(node_filesystem_free_bytes{fstype=~"ext4|xfs"} / node_filesystem_size_bytes{fstype=~"ext4|xfs"})) * 100 > 80
    for: 5m
    labels: 
      severity: warning
    annotations:
      summary: "{{ $labels.instance }}磁盘使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} 磁盘使用率大于80%,(当前值: {{ $value }})"
  - alert: Disk使用率
    expr: (1-(node_filesystem_free_bytes{fstype=~"ext4|xfs"} / node_filesystem_size_bytes{fstype=~"ext4|xfs"})) * 100 > 90
    for: 5m
    labels: 
      severity: critical
    annotations:
      summary: "{{ $labels.instance }}磁盘使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} 磁盘使用率大于90%,(当前值: {{ $value }})"

  - alert: Inode使用率
    expr: node_filesystem_files_free{mountpoint ="/"} / node_filesystem_files{mountpoint ="/"} * 100 < 20
    for: 5m
    labels:
      severity: warning
    annotations:
      summary: "{{ $labels.instance }}Inode使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} Inode使用率大于80%,(当前剩余: {{ $value }})"
  - alert: Inode使用率
    expr: node_filesystem_files_free{mountpoint ="/"} / node_filesystem_files{mountpoint ="/"} * 100 < 10
    for: 5m
    labels:
      severity: critical
    annotations:
      summary: "{{ $labels.instance }}Inode使用率过高"
      description: "{{ $labels.instance }}:job {{ $labels.job }} Inode使用率大于90%,(当前剩余: {{ $value }})"

  - alert: IO性能
    expr: 100-(avg(irate(node_disk_io_time_seconds_total[1m])) by(instance)* 100) < 60
    for: 10m
    labels:
      severity: warning
    annotations:
      summary: "{{$labels.instance}} 流入磁盘IO使用率过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }} 流入磁盘IO大于60%(目前使用:{{$value}})"
  - alert: IO性能
    expr: 100-(avg(irate(node_disk_io_time_seconds_total[1m])) by(instance)* 100) < 80
    for: 10m
    labels:
      severity: critical
    annotations:
      summary: "{{$labels.instance}} 流入磁盘IO使用率过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }} 流入磁盘IO大于80%(目前使用:{{$value}})"

  - alert: 网络流入
    expr: ((sum(rate (node_network_receive_bytes_total{device!~'tap.*|veth.*|br.*|docker.*|virbr*|lo*'}[5m])) by (instance)) / 100) > 76800
    for: 1m
    labels:
      severity: warning
    annotations:
      summary: "{{$labels.instance}} 流入网络带宽过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }}流入网络带宽持续5分钟高于75M. RX带宽使用率{{$value}}"
  - alert: 网络流入
    expr: ((sum(rate (node_network_receive_bytes_total{device!~'tap.*|veth.*|br.*|docker.*|virbr*|lo*'}[5m])) by (instance)) / 100) > 102400
    for: 1m
    labels:
      severity: critical
    annotations:
      summary: "{{$labels.instance}} 流入网络带宽过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }}流入网络带宽持续5分钟高于100M. RX带宽使用率{{$value}}"

  - alert: 网络流出
    expr: ((sum(rate (node_network_transmit_bytes_total{device!~'tap.*|veth.*|br.*|docker.*|virbr*|lo*'}[5m])) by (instance)) / 100) > 76800
    for: 1m
    labels:
      severity: warning
    annotations:
      summary: "{{$labels.instance}} 流出网络带宽过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }}流出网络带宽持续5分钟高于75M. RX带宽使用率{{$value}}"
  - alert: 网络流出
    expr: ((sum(rate (node_network_receive_bytes_total{device!~'tap.*|veth.*|br.*|docker.*|virbr*|lo*'}[5m])) by (instance)) / 100) > 102400
    for: 1m
    labels:
      severity: critical
    annotations:
      summary: "{{$labels.instance}} 流出网络带宽过高!"
      description: "{{$labels.instance}}:job {{ $labels.job }}流出网络带宽持续5分钟高于100M. RX带宽使用率{{$value}}"

  - alert: TCP会话
    expr: node_netstat_Tcp_CurrEstab > 800
    for: 1m
    labels:
      severity: warning
    annotations:
      summary: "{{$labels.instance}} TCP_ESTABLISHED太高!"
      description: "{{$labels.instance }}:job {{ $labels.job }} TCP_ESTABLISHED大于800%(目前使用:{{$value}}%)"
  - alert: TCP会话
    expr: node_netstat_Tcp_CurrEstab > 1000
    for: 1m
    labels:
      severity: critical
    annotations:
      summary: "{{$labels.instance}} TCP_ESTABLISHED太高!"
      description: "{{$labels.instance }}:job {{ $labels.job }} TCP_ESTABLISHED大于1000%(目前使用:{{$value}}%)"

配置邮件告警规则

vi alertmanager.yml
global:
  resolve_timeout: 5m
  smtp_smarthost: 'smtp.163.com:25'
  smtp_from: 'willianlacus@163.com'
  smtp_auth_username: 'xxxx@163.com'
  smtp_auth_password: 'xxxxxx'    ---这里使用邮箱授权码,不是密码
  smtp_require_tls: false
route:
  group_by: ['alertname']  # 根据告警规则组名进行分组
  group_wait: 30s  # 分组内第一个告警等待时间,10s内如有第二个告警会合并成一个告警
  group_interval: 10s  # 发送新告警间隔时间
  repeat_interval: 1h  # 重复告警间隔发送时间
  receiver: 'mail'
receivers:
- name: 'mail'
  email_configs:
  - to: 'xxxx@qq.com'
#抑制规则(意思是多个告警,如果alertname和instance相同,只会报critical级别的高级,不报warning级别的告警)
inhibit_rules:
  - source_match:
      severity: 'critical'
    target_match:
      severity: 'warning'
    equal: ['alertname', 'instance']

检查告警规则

cd /usr/local/prometheus
./promtool check config prometheus.yml
Checking prometheus.yml
  SUCCESS: 1 rule files found

Checking rules/general.yml
  SUCCESS: 17 rules found
---没有额外报错说明没问题

启动alertmanager

systemctl start alertmanager
ststemctl enable alertmanager

2. 告警状态

• Inactive:这里什么都没有发生。
• Pending:已触发阈值,但未满足告警持续时间
• Firing:已触发阈值且满足告警持续时间。警报发送给接受者。

告警状态

浏览器访问alertmanager:
IP:9093

image.png

浏览器访问prometheus查看,可以看到前面配置的告警规则和告警状态

image.png

3. 测试告警

vi /usr/local/prometheus/rules/general.yml    ---把内存warning规则降低到30
(100 - (((node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes)/node_memory_MemTotal_bytes) * 100)) > 30

ps aux | grep prometheus    ---查看prometheus进程的PID号
kill -HUP prometheus进程PID    ---刷新prometheus的配置

查看Status--Rules,可以看到已经修改了

image.png

查看Alerts,可以看到有几个变成PENDING状态了

image.png

过5分钟收到告警邮件说明成功了

image.png