要求10月12日整改完毕。
1,通道材料堆放混乱
![](https://img.haomeiwen.com/i15219344/aa2bfeb3d092800e.jpg)
2,传料口安全网破损
![](https://img.haomeiwen.com/i15219344/53b2db809fe2da65.jpg)
3,通道区域各类材料和垃圾乱堆
![](https://img.haomeiwen.com/i15219344/d8709399af4f787d.jpg)
4,1栋旁外架,存在连墙件(抱柱)缺失、伸出扣件端头长度不足、立杆弯曲等问题。
![](https://img.haomeiwen.com/i15219344/87b245599ee67aa3.jpg)
5,斜撑区模板施工外侧无防护围栏
![](https://img.haomeiwen.com/i15219344/7dfaa843f69a42f4.jpg)
6,1层电梯通道无防护门或封闭
![](https://img.haomeiwen.com/i15219344/316b47800293e32b.jpg)
7,屋面架构层架体防护栏杆未全部挂满安全网(隐患较大)
![](https://img.haomeiwen.com/i15219344/bf362c610fc1c444.jpg)
8,护栏立杆接头全部在同一水平位置。
![](https://img.haomeiwen.com/i15219344/fdfa53da4f7a19bb.jpg)
9,架构层支架上材料堆放集中(隐患较大)
![](https://img.haomeiwen.com/i15219344/92ab0d5021a460f0.jpg)
10,架构层支撑架立杆自由端长度超过0.5m
![](https://img.haomeiwen.com/i15219344/dda91768919fb21e.jpg)
11,楼梯口缺少防护
![](https://img.haomeiwen.com/i15219344/cd89b4219db44a2c.jpg)
12,爬架断开位置仅用安全网封闭,缺少防护栏杆。
![](https://img.haomeiwen.com/i15219344/f14d942dbe7a4e00.jpg)
同上
![](https://img.haomeiwen.com/i15219344/a6ab2fecee2624bd.jpg)
网友评论