美文网首页
Raid卡操作与介绍

Raid卡操作与介绍

作者: _艾_斯_ | 来源:发表于2022-02-18 15:49 被阅读0次
    Raid卡型号与操作

    Raid卡市场主要是LSI、Adaptec、Highpoint、Promise等厂商提供。Adaptac被PMC收购后,提供的Raid卡即为PMC,简称为P卡。LSI公司提供的Raid卡,即为L卡。

    Raid卡配置操作方式

    Raid配置可以通过BIOS启动后进入Raid的配置页面进行配置,也可以进入系统后通过对应的操作工具进行配置。

    PMC配置操作工具为: arcconf

    LSI配置操作工具为:storcli

    Arcconf介绍

    下载:

    https://storage.microsemi.com/en-us/speed/raid/storage_manager/arcconf_v3_03_23668_zip.php

    使用:
    • arcconf list controller_id 查询RAID卡的基本信息, controller_id 硬盘所在RAID卡的ID

    [root@localhost ~]# arcconf list 1
    Controllers found: 1


    Controller information

    Controller ID : Status, Slot, Mode, Name, SerialNumber, WWN

    Controller 1: : Optimal, Slot 1, RAID (Hide RAW), MSCC Adaptec SmartHBA 2100-8i, 7A4563EDE26, 50000D1703F07180


    Array Information

    Array ID : Status (Interface, TotalSize MB, FreeSpace MB)

    Array 0 : Has Failed Logical Drive (SATA, 19077120 MB, 0 MB)
    Array 1 : Ok (SATA, 9538560 MB, 5343744 MB)


    Logical device information

    Logical ID : Status (RAID, Interface, Size MB) Name

    Logical 0 : Failed (10, Data, 4194304 MB) A
    Logical 1 : Optimal (10, Data, 5344246 MB) B
    Logical 2 : Optimal (1, Data, 2097152 MB) Logical Drive 3


    Physical Device information

    Physical ID : State (Interface, BlockSize, SizeMB, Vendor, Model, Type) WWN, [Location]

    Physical 0,8 : Online (SATA, 512 Bytes, 4769307MB, ATA , HUS726050ALE610 , Hard Drive) 500E004AAAAAAA00, [Enclosure 1, Slot 0(Connector 0:CN0)]
    Physical 0,9 : Online (SATA, 512 Bytes, 4769307MB, ATA , HGST HUS726050AL, Hard Drive) 500E004AAAAAAA01, [Enclosure 1, Slot 1(Connector 0:CN0)]
    Physical 0,10 : Online (SATA, 512 Bytes, 4769307MB, ATA , HGST HUS726050AL, Hard Drive) 500E004AAAAAAA02, [Enclosure 1, Slot 2(Connector 0:CN0)]
    Physical 0,11 : Online (SATA, 512 Bytes, 4769307MB, ATA , HGST HUS726050AL, Hard Drive) 500E004AAAAAAA03, [Enclosure 1, Slot 3(Connector 0:CN0)]
    Physical 0,12 : Online (SATA, 512 Bytes, 4769307MB, ATA , HGST HUS726050AL, Hard Drive) 500E004AAAAAAA04, [Enclosure 1, Slot 4(Connector 0:CN0)]
    Physical 0,13 : Online (SATA, 512 Bytes, 4769307MB, ATA , HGST HUS726050AL, Hard Drive) 500E004AAAAAAA05, [Enclosure 1, Slot 5(Connector 0:CN0)]
    Physical 2,0 : Ready (SES2, Not Applicable, Not Applicable, 12G SAS, Expander, Enclosure Services Device) 500E004AAAAAAA1F, [Connector 0:CN0, Enclosure 1]
    Physical 2,3 : Ready (SES2, Not Applicable, Not Applicable, MSCC , Virtual SGPIO, Enclosure Services Device) 50000D1703F07180, [Not Applicable]

    Command completed successfully.</pre>

    • arcconf getconfig controller_id AD 查询RAID卡的基本信息
    命令格式 功能
    arcconf getconfig controller_id AD 查询适配器信息
    arcconf getconfig controller_id LD 查询所有LD的信息
    arcconf getconfig controller_id LD LD_id 查询特定LD的信息
    arcconf getconfig controller_id PD 查询所有物理硬盘的信息
    arcconf getconfig controller_id PD physical_id 查询特定物理硬盘的信息
    arcconf getconfig controller_id AR 查询所有Array的信息
    arcconf getconfig controller_id AR AR_id 查询特定Array的信息
    • arcconf setcontrollermode controller_id mode 设置RAID卡工作模式 , 默认为“Mixed” 。 mode = 2: HBA 3: RAID 5: Mixed

    ./arcconf setcontrollermode 1 3
    Controllers found: 1

    Command completed successfully.</pre>

    • arcconf getconfig 1 查询raid卡工作模式
    • arcconf list 查询所有适用arcconf工具的RAID卡

    [root@localhost ~]# arcconf list
    Controllers found: 1


    Controller information

    Controller ID : Status, Slot, Mode, Name, SerialNumber, WWN

    Controller 1: : Optimal, Slot 1, Mixed, MSCC Adaptec SmartHBA 2100-8i, 7A4563EDE26, 50000D1703F07180

    Command completed successfully.</pre>

    • arcconf setboot controller_id logicaldrive LD_id type boot_type 设置启动盘, LD_id 为 LD的ID , boot_type 为 启动项的类型 , Primary : 将LD或PD设置为第一启动设备, Secondary :将LD或PD设置为第二启动设备。
    • arcconf setboot controller_id device physical_id type boot_type 设置启动盘, physical_id 为 硬盘的physical ID ,boot_type 为 启动项的类型,Primary : 将LD或PD设置为第一启动设备, Secondary :将LD或PD设置为第二启动设备。

    [root@localhost ~]# arcconf setboot 1 logicaldrive 1 type primary
    Controllers found: 1
    Do you wish to change the boot type of the selected device.
    Press y, then ENTER to continue or press ENTER to abort: y

    Command completed successfully.</pre>

    • arcconf setarrayparam controller_id array_id sparetype mode 设置磁盘为热备模式,mode 热备盘的类型 , 1:Dedicated 2:Autoreplace

    [root@localhost ~]# arcconf setarrayparam 1 0 sparetype 1
    Controllers found: 1

    Command completed successfully.
    [root@localhost ~]#</pre>

    磁盘电灯:
    命令 功能
    arcconf identify controller_id device physical_id time time 对特定的物理硬盘进行点灯,time为可选项表示点灯持续的时间,单位为秒。
    arcconf identify controller_id device physical_id 对特定的物理硬盘持续点灯,按任意键会停止点灯。
    arcconf identify controller_id all time time 对所有的物理硬盘进行点灯,time为可选项表示点灯持续的时间,单位为秒。
    arcconf identify controller_id all stop 对所有的物理硬盘停止点灯
    arcconf identify controller_id logicaldrive LD_id time time 对特定的LD进行点灯,time为可选项表示点灯持续的时间,单位为秒。
    arcconf identify controller_id logicaldrive LD_id 对特定的LD停止点灯
    arcconf identify controller_id array array_id time time 对特定的Array进行点灯,time为可选项表示点灯持续的时间,单位为秒。
    arcconf identify controller_id array array_id 对特定的Array停止点灯

    [root@localhost ~]# ./arcconf identify 1 device 0 0
    Controllers found: 1
    Only devices managed by an enclosure processor may be identified
    The specified device(s) is/are blinking.
    Press any key to stop the blinking.</pre>

    创建和删除raid
    • arcconf create controller_id logicaldrive option size level physical_id physical_id...... 创建raid, option为可以设置的选项: Stripesize 条带大小,取值为 16/32/64/128/256/512/1024 ; Name LD的名称; LDcache Controller Cache ; SSDOverProvisioningOptimization SSD的特性,取值为 enable / disable 只有当RAID组由SSD组成时,才能设置该属性。 该选项设置为“Enabled”后,会在数据写入SSD之前重新分配所有使用的块来优化SSD,可以加快初始化的速度。 DataLD 被加速的LD的ID
    • arcconf delete controller_id logicaldrive ld_id noprompt 删除raid

    [root@localhost ~]# ./arcconf create 1 logicaldrive max 0 0 7
    Controllers found: 1

    Do you want to add a logical device to the configuration?
    Press y, then ENTER to continue or press ENTER to abort: y

    Creating logical device: LogicalDrv 1

    Command completed successfully.

    [root@localhost ~]# ./arcconf delete 1 logicaldrive 1 noprompt
    Controllers found: 1

    WARNING: Deleting this logical device will automatically delete array 1 because it is the only logical device present on that array.
    All data in logical device 1 will be lost.
    Deleting: logical device 1 ("LogicalDrv 1")

    Command completed successfully.</pre>

    磁盘cache:
    • arcconf getconfig controller_id ad 查询cache详情
    • arcconf setcache controller_id drivewritecachepolicy drivetype cachepolicy drivetype cachepolicy... 设置cache, drivetype : 要设置写Cache策略的硬盘类型 , Configured:设置RAID/Mixed模式下RAID组成员盘的写Cache策略。 Unconfigured:设置RAID/Mixed模式下非RAID组成员盘的写Cache策略 。 HBA:设置HBA模式下硬盘的写Cache策略; cachepolicy : 硬盘写Cache策略 , 0:Default(将硬盘的写Cache保持为默认状态) 。 1:Enabled(打开硬盘的写Cache功能) 。 2:Disabled(关闭硬盘的写Cache功能)

    设置Configured状态的硬盘Cache写策略为Enabled,设置Unconfigured状态的硬盘Cache写策略为Disabled

    [root@localhost ~]# ./arcconf setcache 1 drivewritecachepolicy Configured 1 Unconfigured 2
    Controllers found: 1
    Enabling controller drive write cache can increase write performance but risks losing the data in the cache on sudden loss.

    Command completed successfully.

    查询当前的硬盘写Cache策略

    [root@localhost ~]# ./arcconf getconfig 1 ad
    Controllers found: 1


    Controller information

    Controller Statue : Optimal
    Controller Mode :Mixed
    Channle description :SCSI

    ...

    Physical Drive Write Cache Policy Information

    Configured Drives :Enabled
    Unconfigured Drives :Disabled
    HBA Drives :Default


    ...</pre>

    storcli介绍

    安装:

    官网下载https://www.broadcom.com/site-search?q=storcli rpm包安装

    使用:

    • storcli64 -h 获取帮助信息
    • storcli64 show[all] 显示某一块raid卡的版本、功能、状态、以及raid卡下的物理磁、逻辑盘信息
    • storcli64 /cx show 显示控制器0的信息
    • storcli64 /cx show freespace 显示剩下的磁盘空间
    • storcli64 /cx set rebuildrate=x1 设置rebuildrate速度
    • storcli64 /cx show rebuildrate 显示重建速率
    • storcli64 /cx set patrolread=on or off 开启或关闭patrolread
    • storcli64 /cx set cc=on or off 开启或关闭rate
    • storcli64 /cx download file=filepath 升级raid卡固件,需要重启
    • storcli64 /cx flushcache 清除raid卡、物理磁盘cache
    • storcli64 /cx/eall/sall show 显示物理磁盘信息
    • storcli64 /cx/eall/sall show all 显示详细物理磁盘信息
    • storcli64 /cx/ex/sx set good/offline/online/missing 设置某块磁盘的状态
    • storcli64 /cx/ex/sx start locate 开启定位某块磁盘
    • storcli64 /cx/ex/sx stop locate 关闭磁盘定位
    • storcli64 /cx/ex/sx show rebuild 显示rebuild
    • storcli64 /cx/ex/sx start rebuild 开始rebuild
    • storcli64 /cx/ex/sx stop rebuild 停止rebuild
    • storcli64 /cx/ex/sx add hostsparedrive dgs=x 设置模块磁盘为diskgroup x 的热备盘
    • storcli64 /cx/ex/sx delete hostsparedrive 删除磁盘热备盘
    磁盘JBOD:
    • storcli64 /cx[/ex]/sx set jbod 设置单盘jbod
    • storcli64 /cx[/ex]/sx show jbod 显示单盘jbod

    [root@localhost ~]# /opt/MegaRAID/storcli/storcli64 /c0/e0/s1 show jbod
    CLI Version = 007.1017.0000.0000 May 10, 2019
    Operating system = Linux 3.10.0-957.el7.x86_64
    Controller = 0
    Status = Failure
    Description = No JBODs have been configured

    Detailed Status :


    Drive Status ErrCd ErrMsg

    /c0/e0/s1 Failure 255 Drive is not a JBOD
    --------------------------------------------</pre>

    • storcli64 /cx[/ex]/sx del jbod [force] 删除磁盘jbod模式
    • storcli64 /cx show jbod 显示JBOD配置

    [root@localhost ~]# /opt/MegaRAID/storcli/storcli64 /c0 show jbod
    CLI Version = 007.1017.0000.0000 May 10, 2019
    Operating system = Linux 3.10.0-957.el7.x86_64
    Controller = 0
    Status = Success
    Description = None

    Controller Properties :


    Ctrl_Prop Value

    JBOD OFF
    ----------------</pre>

    • storcli64 /cx set jbod=<on|off> [force] 设置raid控制器为JBOD模式
    • storcli64 /cx show jbodwritecache 显示raid控制器JBOD写cache配置
    • storcli64 /cx set jbodwritecache=on|off|default 设置磁盘写cache
    磁盘CACHE:
    • storcli64 /c0/vall show all 显示raid虚拟设备的详细信息,Write Cache(initial setting)代表为raid卡的写cache,WriteThrough为关闭模式,WriteBack为开启cache,;Disk Cache Policy代表物理磁盘的cache

    [root@localhost ~]# /opt/MegaRAID/storcli/storcli64 /c0/v12 show all
    VD12 Properties :
    ===============
    Strip Size = 256 KB
    Number of Blocks = 7812499456
    VD has Emulated PD = No
    Span Depth = 1
    Number of Drives Per Span = 1
    Write Cache(initial setting) = WriteBack
    Disk Cache Policy = Enabled
    Encryption = None
    Data Protection = Disabled
    Active Operations = None
    Exposed to OS = Yes
    OS Drive Name = /dev/sdm
    Creation Date = 27-04-2018
    Creation Time = 03:20:44 AM
    Emulation type = default
    Cachebypass size = Cachebypass-64k
    Cachebypass Mode = Cachebypass Intelligent
    Is LD Ready for OS Requests = Yes
    SCSI NAA Id = 6101b5442bcc70002275538c1c79b826
    Unmap Enabled = N/A</pre>

    • storcli64 /c0/vall set pdcache=Off/On/Default 配置物理磁盘的cache,Off为关闭,On为开启,Default为默认值,当为Default时,cache取决于物理磁盘的cache,磁盘cache开启,则raid cache是开启的,否则为关闭。SATA磁盘cache默认为开启,SAS磁盘cache默认为关闭状态。
    • storcli64 /c0/vall set wrcache=wt/wb/awb 设置raid卡cache,wt为WriteThrough,wb为WiteBack,awb为AlwaysWriteBack。当cache为WriteBack时,如果raid卡存在电池,则cache为开启状态,如果没有电池则为WriteThrough状态;当cache为AlwaysWriteBack时,raid卡cache为总是开启状态
    • storcli64 /c0/bbu show 查看电容状态

    [root@localhost ~]# /opt/MegaRAID/storcli/storcli64 /c0/bbu show
    CLI Version = 007.1017.0000.0000 May 10, 2019
    Operating system = Linux 3.10.0-957.el7.x86_64
    Controller = 0
    Status = Failure
    Description = None

    Detailed Status :


    Ctrl Status Property ErrMsg ErrCd

    0 Failed - use /cx/cv 255
    --------------------------------------</pre>

    • storcli64 /c0 flushcache  刷新raid卡、物理磁盘cache
    磁盘信息 :
    • storcli64 /c0/e0 show status  获取enclosure下磁盘风扇等设备的状态
    • storcli64 /cx/ex/sx set good/offline/online/missing  设置磁盘的状态

    相关文章

      网友评论

          本文标题:Raid卡操作与介绍